An on-grid system runs in parallel with the grid: it supplies the building's loads first and exports the surplus to the grid, and it shuts down for safety when the grid fails. An off-grid system is independent of the grid: solar panels, batteries and an inverter supply the loads on their own. A hybrid system stays connected to the grid while using a battery to provide backup power during an outage.
Which one is right depends on the site: whether there is a grid, how reliable it is, evening consumption and budget. Below, we compare the three systems from an installer's point of view.
How does an on-grid system work?
In an on-grid system, solar panels produce DC power and an on-grid inverter converts it into AC synchronised with the grid voltage and frequency. There is no battery, so the installation is the simplest and the most economical per unit of installed power. Energy not consumed at the moment of generation is exported to the grid. Where export is not wanted or is limited, the inverter's export power control is used: the Solis S6 5kW Single-Phase On-Grid Inverter supports export power control, and the Jebel 10kW Three-Phase On-Grid Inverter offers export limiting.
On three-phase commercial roofs, a high DC voltage allows long strings. The Solis S5 10kW Three-Phase On-Grid Inverter has a maximum input voltage of 1100 V, an MPPT range of 160–1000 V and a max. efficiency of 98.7%. On the residential side, the single-phase Solis S6 5kW model, with 2 MPPTs and string current of up to 16 A, suits roofs facing two directions, such as east-west. Both Solis models and the Jebel 10kW model have AFCI (DC arc-fault) protection, an important feature that reduces fire risk on rooftop installations.
What happens when the grid fails?
This question shows the clearest difference between the three systems.
- On-grid: The inverter shuts down through anti-islanding protection the moment it loses the grid. This is not a fault but a safety rule: technicians working on the grid are protected from power fed back from the building. Even with sunshine, the building has no electricity during an outage.
- Hybrid: The inverter disconnects from the grid and keeps supplying the loads on the backup output from the battery and PV. In the hybrid inverter models we reviewed, switchover takes less than 10 ms.
- Off-grid: There is no grid, or it is used only as a backup source. The loads are always supplied through the inverter; an outage only means the battery running empty.
Off-grid systems: when do they fit?
Country houses, agricultural irrigation points, telecom base stations and construction sites where there is no grid line, or where bringing one in is expensive, are typical off-grid applications. Because all the energy passes through the battery, battery capacity and the inverter's continuous power must be sized carefully. Suitable models are in the Off-Grid Inverters category.
Jebel 6kW 48V Off-Grid ECO Hybrid Inverter is designed for this use: it offers a 48 V battery (40–60 V range), 1 MPPT, a maximum PV voltage of 500 V, an MPPT range of 60–450 V and up to 9000 W of usable PV power. It works with lead-acid and lithium batteries, has a separate generator port, and up to 12 units can be connected in parallel for large systems. If a grid or generator is available, the battery can be charged from the AC input with up to 140 A. Its protection rating is IP54 and its operating temperature range is -10 ~ +55°C, so it should be mounted in a shaded, ventilated place out of direct rain.
A practical approach to off-grid sizing: work out the daily consumption (kWh), multiply it by the number of days without sun (autonomy) and divide by the battery's usable capacity. Choose a PV power that can recharge the battery on the shortest winter days. Planning generator support for long cloudy periods keeps the system smaller.
Hybrid systems: the middle ground
For users who have a grid but face frequent outages, have high evening consumption or want to raise self-consumption, a hybrid system is the most flexible solution. Surplus energy goes into the battery during the day and is used from the battery in the evening, and critical loads stay supplied during an outage. A hybrid inverter whose battery can be expanded later is also a good start for customers who want to begin on-grid today and add storage tomorrow.
Which system for which site?
During a site survey, three questions usually settle the decision:
- Is there a grid on site? If not, or if the connection is very far away, the only option is an off-grid system.
- Are outages a problem? If the grid is reliable and the goal is a lower bill, an on-grid system is enough. If outages affect critical loads such as a cold chain, pumps, a security system or a home office, a hybrid system is needed.
- When is energy consumed? If most consumption is during the day (factory, office, supermarket), the self-consumption rate of an on-grid system is already high. If consumption shifts to the evening (homes), a battery keeps a larger share of the generated energy in the building.
Commercial and industrial roofs usually start on-grid; if storage may be added later, leave room for it in the panel and the cable routes.
Comparison table
| On-grid | Hybrid | Off-grid | |
|---|---|---|---|
| Grid connection | Required | Yes | None or backup |
| Battery | None | Yes (can be added later) | Mandatory |
| Export to the grid | Yes, can be limited with export control | Yes, can be limited | None |
| During an outage | Shuts down | Backup output runs | Keeps running |
| Typical use | Lower bills, commercial roofs | Homes, areas with outages | Sites without grid, irrigation |
| Installation complexity | Low | Medium | Medium to high |
System components: checklist
- Solar panel: the string's open-circuit voltage in the cold must stay below the inverter's maximum input voltage.
- Solar inverter: on-grid, hybrid or off-grid; single-phase or three-phase, according to the grid connection.
- Lithium battery (LiFePO4): in hybrid and off-grid systems; its voltage must suit the inverter's battery range.
- Solar cable and MC4 connectors: on the DC side, UV-resistant solar cables and connectors, with the same connector type on both sides.
- DC and AC protection: DC isolator, fuses, surge protection, and residual-current and overcurrent protection on the AC side.
- Metering and monitoring: a current transformer or energy meter for export control, Wi-Fi or 4G for remote monitoring.
- Generator (optional): in off-grid systems and in hybrid systems with long outages.
Frequently Asked Questions
Does an on-grid system work during a power outage?
No. An on-grid inverter shuts down when the grid fails because of anti-islanding protection. If you need power during outages, you need a hybrid inverter and a battery.
Can an off-grid system sell electricity to the grid?
No. An off-grid system is designed to supply loads independently, not to feed the grid. If a grid or generator is available, it is used as a backup source to charge the battery and, when needed, to supply the loads directly.
Can a battery be added to an existing on-grid system?
Yes, usually with an AC-coupled hybrid inverter and a battery. Check the compatibility of the existing inverter and the new hybrid inverter at the project stage.
Which system is more economical?
For the same PV power, an on-grid system has the lowest initial investment, because there is no battery. Hybrid and off-grid systems add the cost of the battery, but in return provide power during outages and independence from the grid.
To plan an on-grid, hybrid or off-grid system for your site together, request a quote.