Outdoor battery cabinet with an IP54 protection level, and indoor battery rack with an IP20 protection level, inbuilt lithium-ion batteries, and the BMS
Features:
• Easy installation and maintenance
- Local and remote management,standard rack&module design, front maintenance
• Safety first
- Self-developed 3-level BMS, complex protection, safe and reliable
• High density
- LFP high-capacity Li-Ion battery with aluminum shell,over 130wh/kg
• Long lifespan
- Long cycle life, 6000 cycles *
• Cell balancing technology
- Active cell balancing and passive cell balancing
Datasheet:
|
BC75T BR75T |
BC100T BR100T |
BR138T |
BR145T |
||
Battery module specification |
||||||
Configuration |
12S2P |
|||||
Rated capacity |
200Ah |
|||||
Rated energy |
7.68kWh |
|||||
Rated voltage |
38.4V |
|||||
Voltage range |
33.6~43.8V |
|||||
Rated charge/discharge |
0.5C |
|||||
Rated charge/discharge |
1C(Opt) |
|||||
AC internal resistance |
≤5mΩ |
|||||
Dimension (W/H/D) |
360/285/692mm |
|||||
Weight |
≤74.5kg |
|||||
Battery rack specification |
||||||
Configuration |
10 battery modules +1 BPU |
14 battery modules +1 BPU |
18 battery modules +1 BPU |
19 battery modules +1 BPU |
||
Rated capacity |
200Ah |
|||||
Rated energy |
76.8kWh |
107.52kWh |
138.24kWh |
145.92kWh |
||
Rated voltage |
384V |
537.6V |
691.2V |
729.6V |
||
Voltage range |
336V-438V |
470.4V-613.2V |
604.8V~766.8V |
638.4V~832.2V |
||
Rated charge/discharge |
0.5C |
|||||
Rated charge/discharge |
1C(Opt) |
|||||
AC internal resistance |
≤50mΩ |
|||||
Display |
7"Touch screen |
|||||
BMS |
Included |
|||||
Communication |
CAN |
|||||
Monitoring |
RS485 |
|||||
Max. altitude |
3000m |
|||||
Dimension (W/H/D) mm |
1310/2150/1025 |
1119/2150/660 |
1310/2150/1025 |
1119/2150/660 |
1504/1760/660 |
1504/1760/660 |
Weight |
≤1130kg |
≤877kg |
≤1436kg |
≤1183kg |
≤1547kg |
≤1624kg |
Protection degree |
IP54 |
IP20 |
IP54 |
IP20 |
IP20 |
IP20 |
Balancing methods |
||||||
Passive cell balancing |
Yes |
|||||
Active cell balancing |
Opt |
|||||
BMS parameters on LCD |
||||||
Cell voltage |
Yes |
|||||
Cell high voltage |
Yes |
|||||
Battery SOC |
Yes |
|||||
Cell temperature |
Yes |
|||||
Charge and discharge current |
Yes |
|||||
Cell low voltage |
Yes |
|||||
Total battery voltage |
Yes |
|||||
Fault warning |
Yes |
|||||
Protection |
||||||
Short circuit protection |
Yes |
|||||
Over current protection |
Yes |
|||||
Over charge protection |
Yes |
|||||
Over temperature protection |
Yes |
|||||
Cell over voltage protection |
Yes |
|||||
Cell under voltage protection |
Yes |
|||||
Over discharge protection |
Yes |
|||||
Certificate |
||||||