Solis 8KW Three Phase HV Hybrid Inverter
SolisLog in for pricing
Three Phase High Voltage Energy Storage Inverters
Leading Features:
• Industry leading 50A/10kW max charge/discharge rating
• Automatic UPS switching
• Supports Peak Shaving Mode
• Pre-made Battery, Meter and CAN cabling to reduce installation time
• Supports Unbalanced and Half-Wave Loads on both the Grid and Backup Port
• Compatible with multiple brands of lithium battery models
• Increased battery protection and operation features to extend battery life
S6 Solar inverter that can connect solar panels and a high voltage battery. This inverter will capture the solar during the day and provide power to your home loads and charge the battery. At night it will use the battery to satisfy your home loads. This will prevent you from using any power from the grid and save you from ever paying them a cent! Fight back with the new S6 solar hybrid inverter from Solis.
Features:
- Industry leading 50A/10kW max charge/discharge rating
- Automatic UPS switching
- Supports Peak Shaving Mode
- Pre-made Battery, Meter and CAN cabling to reduce installation time
- Supports Unbalanced and Half-Wave Loads on both the Grid and Backup Port
- Compatible with multiple brands of lithium battery models
- Increased battery protection and operation features to extend battery life
Technical Specifications
S6-EH3P(5-10)K2-H |
||||
Models |
5K |
6K |
8K |
10K |
Input DC (PV side) |
||||
Recommended max. PV array size |
10 kW |
12 kW |
16 kW |
20 kW |
Max. usable PV input power |
8 kW |
9.6 kW |
12.8 kW |
16 kW |
Max. input voltage |
1000 V |
|||
Rated voltage |
600 V |
|||
Start-up voltage |
160 V |
|||
MPPT voltage range |
200-850 V |
|||
Max. input current |
16 A / 16 A |
|||
Max. short circuit current |
24 A / 24 A |
|||
MPPT number/Max. input strings number |
2/2 |
|||
Battery |
||||
Battery type |
Li-ion |
|||
Battery voltage range |
120-600 V |
|||
Max. charge / discharge power |
5 kW |
6 kW |
8 kW |
10 kW |
Max. charge / discharge current |
25 A |
50 A |
||
Communication |
CAN/RS485 |
|||
Output AC (Grid side) |
||||
Rated output power |
5 kW |
6 kW |
8 kW |
10 kW |
Max. apparent output power |
5 kVA |
6 kVA |
8 kVA |
10 kVA |
Rated grid voltage |
3/N/PE, 380 V / 400 V |
|||
Rated grid frequency |
50 Hz / 60 Hz |
|||
Rated grid output current |
7.6 A / 7.2 A |
9.1 A / 8.7 A |
12.2 A / 11.5 A |
15.2 A / 14.4 A |
Max. output current |
7.6 A / 7.2 A |
9.1 A / 8.7 A |
12.2 A / 11.5 A |
15.2 A / 14.4 A |
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
|||
THDi |
<3% |
|||
Input AC (Grid side) |
||||
Max. input power |
7.5 kW |
9 kW |
12 kW |
15 kW |
Rated input current |
11.4 A |
13.8 A |
8.2 A |
22.8 |
Rated input voltage |
3/N/PE, 380 V / 400 V |
|||
Rated input frequency |
50 Hz / 60 Hz |
|||
Output AC (Back-up) |
||||
Rated output power |
5 kW |
6 kW |
8 kW |
10 kW |
Max. apparent output power |
8 kVA, 60 sec |
9.6 kVA, 60 sec |
12.8 kVA, 60 sec |
16 kVA, 60 sec |
Back-up switch time |
<10 ms |
|||
Rated output voltage |
3/N/PE, 380 V / 400 V |
|||
Rated frequency |
50 Hz / 60 Hz |
|||
Rated output current |
7.6 A / 7.2 A |
9.1 A / 8.7 A |
12.2 A / 11.5 A |
15.2 A / 14.4 A |
THDv (@linear load) |
<2% |
|||
Efficiency |
||||
Max. efficiency |
96.5% |
97.0% |
97.5% |
97.9% |
EU efficiency |
96.8% |
97.1% |
97.4% |
97.5% |
BAT charged by PV Max. efficiency |
98.4% |
98.5% |
98.2% |
98.3% |
BAT charged/discharged to AC Max. efficiency |
97.3% |
97.3% |
97.5% |
97.5% |
Protection |
||||
Anti-islanding protection |
Yes |
|||
Output over current protection |
Yes |
|||
Short circuit protection |
Yes |
|||
Integrated AFCI 2.0 |
Optional |
|||
Integrated DC Switch |
Yes |
|||
DC reverse-polarity protection |
Yes |
|||
PV over voltage protection |
Yes |
|||
Battery reverse protection |
Yes |
|||
General Data |
||||
Dimensions (W*H*D) |
600*500*210 mm |
600*500*230 mm |
||
Weight |
27.6 kg |
30.2 kg |
||
Topology |
Transformerless |
|||
Self-consumption (night) |
<25 W |
|||
Operating ambient temperature range |
-25 ~ +60°C |
|||
Relative humidity |
0-95% |
|||
Ingress protection |
IP66 |
|||
Cooling concept |
Natural convection |
|||
Max. operation altitude |
4000 m |
|||
Grid connection standard |
G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA |
|||
Safety/EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 |
|||
Features |
||||
PV connection |
MC4 connector |
|||
Battery connection |
Quick connection plug |
|||
AC connection |
Quick connection plug |
|||
Display |
LED + Bluetooth + APP |
|||
Communication |
CAN, RS485, Optional: Wi-Fi, Cellular, LAN |
- single or three-phase:
- three-phase
- Battery Voltage:
- 120-600 V
- Frequency:
- 50
- Voltage:
- 380