Huawei 20KW Smart String Inverter
HuaweiLog in for pricing
Smart String Inverter
Features:
• Smart
- 8 strings intelligent monitoring
• Efficient
- Max. efficiency 97.6%
• Safe
- Fuse free design
• Reliable
- Type II surge arresters for DC &
Technical Specification |
SUN2000-20KTL-M3 |
Efficiency |
|
Max.efficiency |
97.6% |
European efficiency |
97.2% |
Input |
|
Recommended Max. PV Power |
30,000 Wp |
Max.Input Voltage1 |
750 V |
Max.Current per MPPT |
26A |
Max.Current per Input3 |
20A |
Max. Short Circuit Current per MPPT |
40A |
Start Voltage |
200V |
MPPT Operating Voltage Range2 |
200 V ~ 750V |
Rated Input Voltage |
360 V |
Number of MPP trackers |
8 |
Max.input number per MPP tracker |
4 |
Output |
|
Rated AC Active Power |
20,000W |
Max.AC Apparent Power |
22,000VA |
Max.AC Active Power (cosφ=1) |
22,000W |
Rated Output Voltage |
120 Vac / 208 Vac, 3W/N+PE |
Rated AC Grid Frequency |
127 Vac / 220 Vac, 3W/N+PE |
Rated AC Grid Frequency |
50 Hz / 60Hz |
Max.Output Current |
160.4A@400V,133.7A@480V |
Rated Output Current |
57.2 A / 202 Vac |
Max. Output Current |
63.2 A / 202 Vac |
Adjustable Power Factor Range |
0.8 LG ... 0.8 LD |
Max. Total Harmonic Distortion |
<3% |
Protection |
|
Input-side Disconnection Device |
Yes |
Anti-islanding Protection |
Yes |
AC Overcurrent Protection |
Yes |
DC Reverse-polarity Protection |
Yes |
PV-array String Fault Monitoring |
Yes |
DC Surge Arrester |
TypeII |
AC Surge Arrester |
TypeII |
DC Insulation Resistance Detection |
Yes |
Residual Current Monitoring Unit |
Yes |
Arc Fault Protection |
Yes |
Ripple Receiver Control |
Yes |
Integrated PID Recovery 3 |
Yes |
Communication |
|
Display |
LED indicators ; WLAN adaptor + FusionSolar APP |
RS485 |
Yes |
USB |
Yes |
SmartDongle-4G |
WLAN/Ethernet via Smart Dongle-WLAN-FE (Optional) |
MonitoringBUS(MBUS) |
Yes (Isolation Transformer required) |
General Data |
|
Dimensions(W xHxD) |
640 x 530 x 270 mm (25.2 x 20.9 x 10.6 inch) |
Weight(with mounting plate) |
43 kg (94.8 lb) |
Noise Level |
< 46 dB |
Operating Temperature Range |
-25 ~ + 60 °C (Derating above 45 °C @ Rated output power) |
Cooling Method |
Natural Convection |
Max.Operating Altitude |
0 - 4,000 m (Derating above 3000 m) |
Relative Humidity |
0% RH ~ 100% RH |
Protection Degree |
IP66 |
Topology |
Transformerless |
Nighttime Power Consumption |
≤ 5.5W |
Optimizer Compatibility |
|
DC MBUS Compatible Optimizer |
SUN2000-450W-P |
Standard Compliance (more availableupon request) |
|
Certificate |
EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683 |
- single or three-phase:
- three-phase
- Frequency:
- 50
- Voltage:
- 220