Solis 3KW Single Phase LV Hybrid Inverter, 10 years warranty

Solis
SKU:
S6-EH1P3K-L-PLUS-1
Availability:
4-6 weeks

Log in for pricing

Weight:
31.00 KGS
Width:
48.00 (cm)
Height:
71.00 (cm)
Depth:
38.00 (cm)
Current Stock:
Minimum Purchase:
1 unit

S6-EH1P(3-8)K-L-PLUS series energy storage inverter is suitable for residential PV energy storage system, support up to 32A MPPT current input, suitable for various high power PV panels; 6-stage timed charge and discharge function, integrated battery treatment and protection functions, more friendly to batteries. And can support multiple inverters in parallel to form a single-phase or three-phase system with a maximum power of 48kW. With UPS switching and provides an independent generator interface to make energy applications more reliable. The product provides solutions for demanding power scenarioswith residential energy storage systems.

Technical Specifications

Models

3K

3.6K

5K

6K

8K

Input DC (PV side)

Recommended max. PV array size

6kW

7.2kW

10kW

12kW

16kW

Max. usable PV input power

4.8kW

5.76kW

8kW

9.6kW

12.8kW

Max. input voltage

500 V

Rated voltage

330 V

Start-up voltage

90 V

MPPT voltage range

90-435 V

Max. input current

16 A / 16 A

32 A / 32 A

Max. short circuit current

20 A / 20 A

40 A / 40 A

MPPT number/Max. input strings number

2/2

2/4

Battery

Battery Type

Li-ion / Lead-acid

Battery Voltage Range

40-60 V

Max. Charge / Discharge Power

3 kW

3.6 kW

5 kW

6 kW

8 kW

Max. Charge / Discharge Current

70 A

80 A

112 A

135 A

190 A

Communication

CAN/RS485

Output AC (Grid side)

Rated output power

3 kW

3.6 kW

5 kW

6 kW

8 kW

Max. apparent output power

3 kVA

3.6 kVA

5 kVA

6 kVA

8 kVA

Operation phase

1/N/PE

Rated grid voltage

220 V / 230 V

Rated grid frequency

50 Hz / 60 Hz

Rated grid output current

13.7 A / 13.1 A

16.4 A / 15.7 A

22.8 A / 21.8 A

27.3 A / 26.1 A

36.4 A / 34.8 A

Max. output current

13.7 A / 13.1 A

16.4 A / 15.7 A

22.8 A / 21.8 A

27.3 A / 26.1 A

36.4 A / 34.8 A

Power factor

>0.99 (0.8 leading - 0.8 lagging)

THDi

<2%

Input AC (Grid side)

Input voltage range

187-253 V

Max. input current

21A

25A

32A

40A

50A

Frequency range

45-55 Hz / 55-65 Hz

Output AC (Back-up)

Rated Output Power

3 kW

3.6 kW

5 kW

6 kW

8 kW

Max. apparent output power

2 times of rated power, 10 s

Back-up switch time

<4 ms

Rated output voltage

1/N/PE, 220 V / 230 V

Rated Frequency

50 Hz / 60 Hz

Rated output current

13.7 A / 13.1 A

16.4 A / 15.7 A

22.8 A / 21.8 A

27.3 A / 26.1 A

36.4 A / 34.8 A

Max. AC Passthrough current

35A

35A

40A

40A

50A

THDv (@linear load)

<2%

Efficiency

Max. efficiency

96.2%

EU efficiency

94.7%

BAT charged by PV/AC Max. efficiency

95.3%/94.5%

BAT discharged to AC Max. efficiency

94.9%

Protection

Ground fault monitoring

Yes

DC reverse-polarity protection

Yes

Integrated AFCI 2.0

Optional

Protection class/Over voltage category

I / II (PV and BAT), III (MAINS and BACKUP and GEN)

General Data

 

Dimensions (W*H*D)

335*560*227 mm

Weight

21.6 kg

22.2 kg

Topology

High frequency isolation (for battery)

Operating ambient temperature range

-40 ~ +60°C

Ingress protection

IP66

Cooling Concept

Natural convection

Intelligent redundant fan-cooling

Max. operation altitude

3000 m

Grid connection standard

NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA

Safety/EMC standard

IEC/EN 62109-1/-2, EN 61000-6-2/-3

 

 

10 years
single or three-phase:
single-phase
Battery Voltage:
48
Frequency:
50
Voltage:
220