Solis 255KW Three Phase String Inverter (14 MPPT)
SolisContact us for pricing
Log in for pricing
Solis 255KWthreephase 14MPPTs,withDCswitch
Leading Features:
- > 150% DC/AC ratio
- Night SVG function
- IP66
- DC side supports "Y" connector
- 9/12/14 MPPTs, max. efficiency 99.0%
- High power tracking density 55MPPT/MW
- Compatible with 550W+ bifacial modules
- Power line communication (PLC) (optional)
- Fuse free design, safe and maintenance free
- Remote firmware upgrade with simple operation
- Intelligent string monitoring, smart I-V curve scan
- Built-in PID recovery for better module performance
- Globally recognised branded componentry for longer life
Technical Specifications:
Models |
215K-PLUS |
255K |
255K-PLUS |
Input DC |
|||
Max. input voltage |
1500 V |
||
Rated voltage |
1080 V |
||
Start-up voltage |
500 V |
||
MPPT voltage range |
480-1500 |
||
Max. input current |
9*30 A |
14*26 A |
12*30 A |
Max. short circuit current |
9*50 A |
14*40 A |
12*50 A |
MPPT number/Max. input strings number |
9/18 |
14/28 |
12/24 |
Output AC |
|||
Output power |
215 kVA@30°C / 205 kVA@40°C / 195 kVA@50°C |
255 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C |
|
Rated grid voltage |
3/PE, 800 V |
||
Grid voltage range |
640-920 V |
||
Rated grid frequency |
50 Hz |
||
Max. output current |
155.2 A |
184.0 A |
|
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
||
THDi |
<3% |
||
Efficiency |
|||
Max. efficiency |
99.0% |
||
EU efficiency |
98.8% |
98.7% |
98.8% |
Protection |
|||
DC reverse-polarity protection |
Yes |
||
Short circuit protection |
Yes |
||
Output over current protection |
Yes |
||
Surge protection |
DC Type II / AC Type II |
||
Grid monitoring |
Yes |
||
Anti-islanding protection |
Yes |
||
Temperature protection |
Yes |
||
Strings monitoring |
Yes |
||
I/V Curve scanning |
Yes |
||
Night time SVG function |
Yes |
||
Integrated PID recovery |
Yes |
||
Integrated DC switch |
Yes |
||
General Data |
|||
Dimensions (W*H*D) |
1125*770*384 mm |
||
Weight |
109 kg |
113 kg |
|
Topology |
Transformerless |
||
Self-consumption (night) |
<2 W |
||
Operating ambient temperature range |
-30 ~ +60°C |
||
Relative humidity |
0-100% |
||
Ingress protection |
IP66 |
||
Cooling concept |
Intelligent redundant fan-cooling |
||
Max. operation altitude |
4000 m |
||
Grid connection standard |
EN50549, G99, AS4777.2, VDE0126, IEC61727, VDE4110, CEA 2019 |
||
Safety/EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 |
||
Features |
|||
DC connection |
MC4 connector |
||
AC connection |
OT terminal (max. 300 mm2) |
||
Display |
LCD |
||
Communication |
RS485, Optional: PLC |
- single or three-phase:
- three-phase
- Frequency:
- 50
- Voltage:
- 800