Solis 8KW Single Phase String Inverter
SolisLog in for pricing
Solis 8KWsinglephaseDualMPPT,withDCSwitch
Features:
- Max.efficiency 98.0%
- Max.input current 14A
- 3 MPPT design with precise MPPT algorithm
- AFCI protection, proactively reduces fire risk
- Compact and lightweight
- Wide voltage range and low startup voltage
- Friendly and adaptable connection to the grid
Datasheet:
Models |
7K |
8K |
9K |
10K |
Input DC |
||||
Recommended max. PV power |
10.5 kW |
12 kW |
13.5 kW |
15 kW |
Max. input voltage |
600 V |
|||
Rated voltage |
330 V |
|||
Start-up voltage |
120 V |
|||
MPPT voltage range |
100-500 V |
|||
Max. input current |
14 A / 14 A / 14 A |
|||
Max. short circuit current |
22 A / 22 A / 22 A |
|||
MPPT number/Max. input strings number |
3 / 3 |
|||
Output AC |
||||
Rated output power |
7 kW |
8 kW |
9 kW |
10 kW |
Max. apparent output power |
7.7 kVA |
8.8 kVA |
9.9 kVA |
10 kVA |
Max. output power |
7.7 kW |
8.8 kW |
9.9 kW |
10 kW |
Rated grid voltage |
1/N/PE, 220 V / 230 V |
|||
Rated grid frequency |
50 Hz / 60 Hz |
|||
Rated grid output current |
31.8 A / 30.4 A |
36.4 A / 34.8 A |
40.9 A / 39.1 A |
45.5 A / 43.5 A |
Max. output current |
33.7 A |
36.6 A |
41.3 A |
45.9 A |
Power factor |
>0.99 (0.8 leading - 0.8 lagging) |
|||
THDi |
<3% |
|||
Efficiency |
||||
Max. efficiency |
98.0% |
|||
EU efficiency |
97.1% |
|||
Protection |
||||
DC reverse-polarity protection |
Yes |
|||
Short circuit protection |
Yes |
|||
Output over current protection |
Yes |
|||
Surge protection |
Yes |
|||
Grid Monitoring |
Yes |
|||
Anti-islanding protection |
Yes |
|||
Temperature Protection |
Yes |
|||
Integrated AFCI (DC arc-fault circuit protection) |
Yes (1) |
|||
Integrated DC switch |
Optional |
|||
General Data |
||||
Dimensions (W*H*D) |
333*579*253 mm |
|||
Weight |
18.5 kg |
|||
Topology |
Transformerless |
|||
Self-consumption (night) |
<1 W |
|||
Operating ambient temperature range |
-25 ~ +60°C |
|||
Relative Humidity |
0-100% |
|||
Ingress protection |
IP66 |
|||
Cooling concept |
Natural Convection |
|||
Max. operation altitude |
4000 m |
|||
Grid connection standard |
G99, EN 50549-1, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530 |
|||
Safety/EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 |
|||
Features |
||||
DC connection |
MC4 connector |
|||
AC connection |
OT Terminal |
|||
Display |
LCD |
|||
Communication |
RS485, Optional: Wi-Fi, GPRS |
- single or three-phase:
- single-phase
- Frequency:
- 50
- Voltage:
- 220