DEYE 100KW, 380V Three Phase String Inverter ( 6 MPPT )

DEYE
SKU:
SUN-100K-G03
Availability:
In Stock

Log in for pricing

Weight:
96.00 KGS
Width:
109.00 (cm)
Height:
84.00 (cm)
Depth:
55.00 (cm)
Current Stock:
Minimum Purchase:
1 unit

DOWNLOAD DATASHEET

100KW, 380V Three Phase String Inverter, ALL STRING INVERTER AND HYBRID INVERTER ARE INCLUDED WIFI PLUG

Features:

  • 6 MPP trackers, Max. efficiency up to 98.8%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Anti-PID function (Optional)
  • Type II DC/AC SPD

Datasheet:

Model

SUN-70K-G03 SUN-75K-G03 SUN-80K-G03 SUN-90K-G03 SUN-100K-G03 SUN-110K-G03

Input Side

 

Max. DC Input Power(kW)

91

97.5

104

135

150

150

Max. DC Input Voltage (V)

1000

Start-up DC Input Voltage(V)

250

MPPT Operating Range(V)

200~850

Max. DC Input Current(A)

40+40+40+40

40+40+40+40+40+40

Max. Short Circuit Current (A)

60+60+60+60

60+60+60+60+60+60

Number of MPPT/Strings per MPPT

6 / 4

Output Side

Rated Output Power(kW)

70

75

80

90

100

110

Max. Active Power(kW)

77

82.5

88

99

110

121

Nominal Output Voltage / Range (V)

3L/N/PE 220/380V, 230/400V

Rated Grid Frequency(Hz)

50 / 60 (Optional)

Operating Phase

Three phase

Rated AC Grid Output Current(A)

106.1/101.5

113.6/108.7

121.2/115.9

136.4/130.4

151.5/144.9

166.7/159.4

Max. AC Output Current(A)

116.7/111.6

125/119.6

133.3/127.5

150/143.5

166.7/159.4

183.3/175.4

Output Power Factor

0.8 leading to 0.8 lagging

Grid Current THD

<3%

DC Injection Current(mA)

<0.5%

Grid Frequency Range

47~52 or 57~62 (Optional)

Efficiency

Max.Efficiency

98.8%

Euro Efficiency

98.3%

MPPT Efficiency

>99%

Protection

DC Reverse-Polarity Protection

Yes

AC Short Circuit Protection

Yes

AC Output Overcurrent Protection

Yes

Output Overvoltage Protection

Yes

Insulation Resistance Protection

Yes

Ground Fault Monitoring

Yes

Islanding Protection

Yes

Temperature Protection

Yes

Integrated DC Switch

Yes

Remote software upload

Yes

Remote change of operating parameters

Yes

Surge protection

DC Type II / AC Type II

General Data

Size(mm)

838W×568H×324D

838W×568H×346D

Weight(kg)

81

Topology

Transformerless

Internal Consumption

<1W (Night)

Running Temperature

-25~65℃, >45℃ derating

Ingress Protection

IP65

Noise Emission(Typical)

<55dB

Cooling Concept

Smart cooling

Max. Operating Altitude Without Derating

2000m

Designed Lifetime

5 years

Grid Connection Standard

CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11

Operating Surroundings Humidity

0-100%

Safety EMC/Standard

IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Features

DC Connection

MC-4 mateable

AC Connection

IP65 rated plug

Display

LCD 240 × 160

Interface

RS485/RS232/Wifi/LAN

 

5 Years + 2 years Nastech exclusive = 7 Years
single or three-phase:
three-phase
Frequency:
50
Voltage:
380